Rad/Flouro/Tomo Rooms currently available for sale All still installed and in good working condition unless otherwise noted

Call Pamela King at 843 884 7972

 

 

Electromed

  • 1994 Electromed Rad Room, MA 1,000, Acoma table model with 4 way elevating table, Linear IV automatic upright collimator, wall bucky, overhead tube crane. Currently installed, working and available for removal now.

 

 

GE

  • 1991 GE Advantix R/F Room, Advantix generator, MA 800, KVP 150, Wall Bucky, 11” ii ceiling suspended, 3 phase  generator, overtable tube replaced in 2005, includes digital recording devise. Currently installed, working and available for removal now.
  • 1990 GE Advantix R/F Room soft film model, 9” ii org., 90/90 tilt, auto collimator, wall bucky, tomo capabilities, Century III, overhead tube replaced in 2003, front and rear load 105mm spot film camera. Currently installed, working and available for removal now.
  • 1992 GE Rad Room, GE generator, adaptable size bucky 14-17, comes with foot switches, phototimed, floating table, comes with all manuals and service records, 3-phase ceiling mounted system, associated X-ray, GE deistalled in 2005 (said it was in great condition). Available for removal now.
  • 1978 GE Rad Room, MST II generator, MA 400, KVP120, RTE table model 4way, 3-phase, tube replaced 2003, service contract with GE. In fair condition. Currently installed, working and available for removal now.

Hydrojust

  • 1993 Hydrojust IV Rad/Flouro Room, Hydrojust IV table, Electromed generator, 12” ii. Currently installed, working and available for removal now.

 

Philips

  • 1990 Philips Maximus Rad/Flouro Room, Maximus generator model, 1976 Diagnost table with tilt and 4-way, 1973 Scopomat collimator, cassette holder, 2 ii 6” and 9” org. compact, was rebuilt in 1989 by Dakota Medical Systems. Currently installed, working and available for removal now.
  • 1995 Philips Integris Cath Rad/Flouro Room, single plane, ceiling mounted table, stepper, 100kw Integris generator, shield, Integris digital system, 15” ii, SRC 120 X-ray tubes replaced in 2002, suspended monitors. Currently installed, working and available for removal now.
  • 1991 Philips Optimus 2000 Poly C2 Cath Lab Rad/Flouro Room, Single plane, ceiling mounted table, CP 100kw generator, shield, DCI 4.X digital system, 9” tri-mode ii, MRC 200 Roto X-ray tubes, injector, suspended monitors. Currently installed, working and available for removal now.

 

 

Picker

  • 1990 Picker Elite Rad/Flouro Room, 1990 MPX generator, Elite table, tri mode ii replaced in 1999, 100mm spot film camera, 14X14 spot film device. Currently installed, working and available for removal now.
  • 1986 Picker Elite Rad/Flouro Room, generator model GX1000 3 phase, quantomat phototimed, Vector B spot film device with front and rear load, 12” Picker ii, pedestal mount replaced in 1999, overhead tube support replaced in 1989, Picker spot film camera, cut film 105mm, ceiling mounted monitors, cassette holder, chest stand, Paush automatic collimator, Puck C phototiming table. Currently installed, working and available for removal now.
  • Picker Rad Room, generator model VX650, 3 phase, max. MA 600, Hi Lo 4 way flat top table, Dunlee overhead tube support, cassette holder, Grafix, Autotatic collimator, Picker phototiming, deinstalled by GE. Was working at time of deinstall and is available for removal now.

Prestilix

  • 1986 Prestilix 1600 Rad/Flouro room, CGR generator, 3 phase, phototimed, Prestilix 1600 table, 2-way phototimed, 9” ii mounted under table, overhead tube (Tubemaster 2002), I monitor TV system, Grafix cassette holder, manual collimator, Prestilix linear tomo capability. Currently installed, working and available for removal now.

Raytheon

  • 1985 Raytheon RME Rad/Flouro room, Volts 240Hz 60 amps generator, stationary table, overhead tube crane. Currently installed, working and available for removal now.
  • 1985 Raytheon Rad Room, Raytheon EXT power table, Raytheon bucky and tube with Machlett collimator, Raytheon wall mount cassette holder (10x12  to 14x17), X-ray film cassettes (4-14x17, 3-10x12, 11x14), Kodak RP X-Omat processor, two film wall mount view box, hot spot light, red dark room light, S&S X-ray product inc. film loading bin (22”x36”), dark room exposed/unexposed pass-thru container, 2 full lead aprons, lead vest, lead neck cover, pair lead gloves, wall holder for protective clothing. Currently installed, working and available for removal now.

 

Shimadzu

  • 1991 Shimadzu UD Rad room, high frequency generator, UTM 80 table, 90/15, 30X overhead tube crane, wall bucky, phototimed table and wall bucky, upgraded manual cassette trays. Currently installed, working and available for removal now.

 

 

Call Pamela King/JP International 843 884 7972 for further information

 

If you don’t see what you need here, please call us