GE
- 1999 GE GXI, dual
console, Advantix 2.0x4.0, Z Advantix Workstation, Invision
Ceiling Mount injector, Xact table, new x ray tube 2006, been under GE
service, was in good working condition prior to OEM deinstall, currently in
warehouse.
- 2002 GE lightspeed plus, single console, tube age Sept 2005, quad
slice, can do reconstructions. Currently installed, working and available for
removal now.
- 2004 GE Discovery
ST-8 PET CT mobile – will do
viability studies with FDG, has BGO crystal, 53 feet long including generator
and A/C, 102 inches wide, dual injection hot lab. Comes with
PET
CT fusion Image
registration software that allows you to bring in old CT scans and fuse them
in. Xeleris workstation. Available for removal
now.
Siemens
- 2004 Siemens ECAT
Accel mobile PET in trailer 48x8. Gantry mounting plate(EXACT/EXACT HR+),
isolation transformer(US), Gantry air/water chiller(60Hz), ACCEL Sources
kit(1st Fill.), uninterruptible power supply, condonics imager
large format, Ethernet interface hub (10/100 Mbit) E.Soft V, English language
kit, e.soft, 21monitor, e.soft archival, CD-R, e.soft PET package, ECAT to
DICOM image translator, myocardio perfusion(for advanced studies you need
gantry software 30K upgrade), LSO crystal, uptake and incubation area, extra
spark workstation. Working and available now.
- 1998 Siemens Somatom Plus 4 Expert CT single slice scanner with UFC
Detectors Tube 3 years old. Only
standard options Gantry count 9, Container IMS Storage Device HD/MOD Endast
Operator Console Software version VC10C. Currently installed, working and
available for removal now.
- 1996 Siemens Somatom
Plus 4 Power CT Scanner single slice .50/60Hz system.
Total gantry scan seconds 1,296,721 as of May 2004. Image processor model SM15
with 1.7GB MOD drive for image archive. Does not include an imager or laser.
Currently deinstalled
- 2001 Siemens Emotion
Duo Helical Two Detector, .8 sec Helical scan speed, software upgraded
9/1/2003, gantry scans 421,0980 sec, type scans 347,329 sec tube is 2.5 years
old, currently installed and working fine, available now for
removal
Philips
- 1997 Philips Tomoscan M Portable CT, single operator consaole, 6.0 mhu tube, SunSparc/Image Processor computer, 5.25 inch optical disk
256 gray scale 512x512 display matrix, lightweight scanning gantry, scan times
2,4,6 sec, patient support, needs batteries (about 5K cost) was removed 2
years ago and is currently in storage.
- 2000 Philips Aura,
tube age 2005, tube slice count 209,000, gantry slice count 1,292,940, single
slice system, under Phillips service. Currently installed, working and
available for removal now.
- 2000 Philips MX 8000
Quad, simultaneous four slice acquisition, 120,000 scan seconds on a Akron B
6.5MHU Tube, .8 Second 360 degree scan time, slimscan 0.5mm slice thickness,
60kW high frequency generator, MX view workstation, coronary artery calcium
scoring (CAC), heart-beat-CS Cardiac scoring package, cardiac gating, cardiac
score, voyager 3D-Endoscopic visualization package, Voyager 4D Angio
Visualization package, 18.0 GB raw data storage memory, 100 seconds of
continuous multi-slice capability, ESP IIQ Easy scan planning, DICOM3.0/DICOM
modality work list, ultraimage, BolusPro Ultra, 4-D Angio volume rendering, 3D
imaging, Denta CT. Currently installed, working fine and available for removal
now.
- 2002 Philips Diamond
Select ACQSIM CT system, ACQSIM CT Gantry(85cm Gantry, 60cm FOV), 56kW
generator option, Rhino 6.5A tube, Operator’s table(54”x30”) and operator’s
chair, ZAP ultra spiral package, flat table insert, ACQSIM CT low voltage slip
ring gantry, patient table, operator’s console, 64 Bit sun UltraSPARC RISC processor, 18GB image disk-18GB system
disk-18GB raw data disk, 8mm cassette tape drive, 4 to 5 second
reconstruction, ESP graphic user interface, oracle Rx, spiral page, spiral
profile, ultra image, MPR (Multiplaner Reformatting, DICOM 3.0
Send/Receive/Query/Retrieve, DIOM print interface, patient positioning
accessories, 85cm Gantry aperture for easy patient access, positioning and
immobilization, 60cm field of view, plus/minus 30 degree Gantry tilt-roaring
silence DAS with DC, RAD technology minimizes electronic noise and provides
maximum resolution for single slice and spiral scanning, consistent image
quality, special resolution- 15Lp/cm spatial resolution in axial and spiral
scan modes, low contrast resolution, low voltage slip ring rotation for low
noise image quality; fast installation and easy fitting X-Ray System 56kW
Generator 56kW high frequency, on-board, solid state generator. Currently
installed, working and available for removal now.
Toshiba
- 1996 Toshiba X-speed,
single console, 115,000 tube slice count, Toshiba computer – no disk drives or
storage, not spiral. Currently installed, working and available for removal
now.
Carbon Fiber Couch
Top
- For GE Lightspeed
scanner, Med Tech 2001 in excellent condition. Available
now.