Cath Labs available for sale
GE
- 1996 GE Advantix
Angio room, Omega table model, digital, wall bucky, 40cm ii ceiling
suspended, wall-mounted c-arm, vascular software, LCA positioner, original
parts, service contract with GE. Currently installed, working and
available for removal now.
- 2000 GE Innova Cath
Lab, digital detector replaced in 2003, perfect working condition before
deinstallation. Deinstalled by GE
engineer. Available for removal now.
- 1998 GE Advantix
Tilt-C plus remote R/F room with Angio system, Advantix generator,
Advantix E, 16” ii, MX150 x-ray tube, DRS 3.0 digital, flouro room
provides live images, uses fluorography (uses a lower dose of radiation),
digital imaging with remote viewing capabilities, multipurpose system used
for remote, R/F, radiology, fluoroscopy, and angiographic study, under
service contract. Currently installed, working and available for removal.
Philips
- 2000 Philips H5000,
OMCP generator, Angio Diagnost 5 4-way float non-tilting table model,
single, digital system, tri mode ii (5, 7, 9”), floor mounted C-arm, Visub
digital imaging chain, CCD camera. Currently installed, working and
available for removal.
- 1990 Philips Angio
room, Philips Super 100CP generator, Philips MRE 180A floating stepping
table model, 1990 Philips parallel u-arms, 1990 ii (11, 10, 6”), 3 Philips
1990 x-ray tube, air cooled, Oldelft camera, 2-20” monitors, ceiling
mounted system, Biplane Siemens film changer, Medrad Mark V injector
system, long leg changer, dual printers. Currently installed, working and
available for removal.
Siemens
- 2001 Siemens single
plane cardiac cath lab, Polydoros
IS generator, Coroskop HIP TOP floor mounted
stand, Sirecon 23-3 Tri-mode ii, Koordinate table, Hicor TOP
digital system. Currently installed, working and available for removal Oct
2006.
- 1998 Siemens Polystar TOP remote R/F and Angio
multipose system, floor mounted universal C-arm
with vertically adjustable single sided freely suspended table top
(90/90), Sirecon 40-4 ii (40, 30, 22, and 17cm
fields), Polydoros generator, Megalix X-ray tube, Flourospot
TOP digital, 2 monitors in room (one in control area, one in suspension
room), Dicom software. Deinstalled in November 2004. Was working properly at time of
deinstall. Available for removal now.
- 1995 Siemens Multistar TOP, Polytron TOP
MA 1000 KVP 100, Koordinate U 4-way table model.
Flouro only, Sirecon
40-4HD and 33-4HDR imaging chain, 16” ii, ceiling mounted, all digital, GE
service contract. Currently installed, working and available for removal.
CALL
Pamela King
JP International for further information (843)
884-7972